Updated Nov 24, 2026· 30 min read

Key takeaways

  • Learn how to winterize a sprinkler system step by step by valve type: manual drains, automatic drains, and a safe blowout with the right pressure for each zone.

The short answer to how to winterize a sprinkler system is this: shut off the irrigation water, get every drop you can out of the pipes, valves, and heads before the first hard freeze, protect the backflow preventer by hand, and leave the controller powered but set not to run. That answer fits in a snippet. What a snippet cannot tell you is which draining steps apply to your yard, because the right sequence changes completely depending on the valves buried in it. A system with manual drain valves is opened valve by valve at its low points. A system with automatic drains mostly drains itself, but still needs checking. A system with electric valves, check valves, or no reliable slope usually needs a compressed-air blowout, done zone by zone at a pressure matched to its pipe type. Doing the steps for the wrong valve type, or doing the right steps in the wrong order, is how a system that was supposedly winterized still cracks in January.

This guide is organised around that decision. First, identify which drain valves, zone valves, and backflow device you actually have, using the tables below. Then follow only the procedure that matches, in the order given. Every pressure, time, and temperature below is attributed to the maker or authority that published it, because with pressurised air the difference between a safe number and a damaging one is not a matter of opinion.

Why trapped water breaks a sprinkler system

Colorado State University Extension explains the physics plainly: most substances contract as they get cold, but water contracts only until it reaches 39 degrees Fahrenheit, and on further cooling to 32 degrees Fahrenheit it expands as it turns to ice. The Extension notes that water increases in volume by about one-eleventh when it freezes, so 11 cubic feet of water forms roughly 12 cubic feet of ice. That expansion force, the Extension says, is sufficient to burst pipes and fittings, crack valves, and split sprinkler and pump cases open.

Notice what that means for your system. The danger is not cold air touching a pipe. The danger is still water sitting inside a closed pipe, a valve body, a sprinkler case, or a backflow preventer when the temperature falls. An empty pipe can get just as cold without damage. That is why every method in this guide has the same goal, stated by Colorado State University Extension as expelling all the water from the irrigation system and equipment, and why the methods differ only in how completely, and how verifiably, they achieve it.

It also explains why above-ground parts fail first and most expensively. Buried pipe is buffered by soil. The backflow preventer, the manifold, and any exposed risers sit in open air, cool fastest, and hold water in small, rigid brass and plastic passages. Protecting those parts is not an optional extra at the end of the job. For many homes it is the part of the job most likely to prevent a spring repair bill, and it has its own procedure later in this guide, separate from draining the lines in the ground.

Timing follows from the same logic. HGTV, drawing on Rain Bird guidance, advises getting all the water out of pipes and sprinklers before freezing temperatures arrive, and aiming to prepare irrigation for winter about the time autumn leaves start falling. Do not wait for a forecast of a severe freeze to begin. A single night cold enough to freeze water in an exposed backflow preventer can do damage while the buried lines are still safe, and a blowout booked or borrowed at the last minute is a blowout done in a hurry, which is when pressure mistakes happen.

Step zero: identify your valves before you touch anything

The click-worthy part of this job, and the part most short guides skip, is identification. Four different valve decisions determine your procedure: how your lines drain, how your zones are controlled, what backflow device you have, and how your water is shut off. Work through the table below at your valve boxes and manifold before you start, and write down what you find. If you cannot identify a part, that itself is information: Colorado State University Extension and the makers both point owners who are unsure of their system type toward the blowout method, or toward a professional, rather than toward guessing with drain valves.

What to identify How to recognise it What it changes in your procedure
Manual drain valves Small valves or drain caps at the lowest points of the mainline and lateral lines, often in valve boxes or at line ends You open each one by hand, slowly, after relieving pressure; see the manual drain procedure below
Automatic drain valves Spring-loaded devices installed on sprinkler heads or pipes, per Rain Bird; they open whenever pressure drops The lines drain themselves each time the system shuts off; your job is verification, not opening valves
Electric zone valves with a controller A timer or controller wired to solenoid valves, usually grouped in a manifold box Colorado State University Extension says systems with electric valves must be blown out, because only air clears water sitting on top of the valve diaphragm
Check valves in the heads Heads that hold water back instead of letting it drain to the low point of the zone Drain valves cannot empty these lines; the water must be blown out through the heads
Stop-and-waste shutoff A shutoff between the water supply and the backflow device, in a basement, crawl space, or underground valve box, per Colorado State University Extension Closing it both stops the supply and opens a waste drain; it may sit about 5 feet down and need a long key, and the Extension warns not to force it
Backflow device type: AVB, PVB, or RP AVBs sit downstream of each valve; PVB and RP devices are the larger assemblies, usually above ground near the house, with test cocks protruding from the side AVBs are winterized with the zone blowout; PVB and RP devices must never be blown out with compressed air and are drained by hand instead

Two identification traps deserve emphasis. First, a system can have more than one drain type at once: manual drains on the mainline are common even on systems whose zones are blown out, and Rain Bird’s manual procedure is specifically written for mainline drains. Finding a manual drain does not prove the whole system drains by gravity. Second, the presence of automatic drains does not prove they still work. Rain Bird warns that excessive puddling on the surface of the soil can indicate a drain has become stuck open, and a drain stuck closed fails silently, leaving a line full of water that you assume is empty.

Colorado State University Extension is blunt about the limits of both gravity methods: drain valves rely on a properly installed system laid to grade with no humps in the pipe to trap water in low areas, buried pipe tends to shift with time, and there is no way to visually inspect lines once draining is complete. The Extension therefore says not to trust manual or automatic drain valves alone, and calls compressed air the only positive way to be sure enough water has been expelled. Read the drain procedures below as necessary steps, especially for the mainline, but in a cold climate read the blowout procedure as the verification that the drains did their job.

What you need, and the safety rules that come first

Gather everything before you shut the water off, because several steps should follow each other without a long pause while pressure is relieved. For all systems you need eye protection, a bucket for draining the mainline indoors, and a way to label or note the position of each valve you change. For a blowout you also need an air compressor with a pressure regulator, a blowout adapter that fits your system’s blowout fitting, and enough air hose to reach it. HGTV notes that faucet-side equipment such as timers, filters, and pressure regulators should be removed after draining and stored indoors, so have a place ready for those parts as well.

  • Eye protection, always. Rain Bird requires it for opening manual drains, because those systems are pressurised and can cause injury if opened before pressure is relieved, and again for blowouts, where debris can fly. Colorado State University Extension closes its guidance with the same caution.
  • Never stand over components during a blowout. Rain Bird states this directly: do not stand over any irrigation components while air is flowing through them.
  • Open a zone before introducing air. Rain Bird instructs you to open one valve before starting the compressor, so pressure has somewhere to go and does not damage the system or blow a head apart.
  • Regulate the pressure, do not estimate it. Every procedure below assumes a regulator you can set and read. If your compressor cannot be regulated to the limits in the pressure table, it is the wrong tool for this job.
  • Keep people and pets clear. Colorado State University Extension notes that blowing out a system can upset pets because of the whistling, and advises taking care to protect pets from running off during winterization.
  • Know when to stop and hire a pro. Rain Bird advises contacting a professional if you do not have the right equipment or are worried about doing something wrong. That is not a sales line; it is the correct call for a system you cannot identify, a shutoff you cannot find, or a compressor you cannot regulate.

One more preparation step saves confusion later: photograph or sketch your manifold, backflow preventer, and controller settings before you change anything. In spring you will need to reverse several of these positions, including test cocks and ball valves left half open, and a photo taken now is far more reliable than memory in April. Note also which zone is farthest from the air connection and which is at the highest elevation, because the blowout sequence starts there.

Step 1: shut off the irrigation water supply

Every method starts here, and the order matters: water off first, pressure relieved second, drains opened third. Colorado State University Extension directs you to start by turning off the water supply to the system, at the stop-and-waste valve or drain installed between the water supply and the backflow device. That valve may be located in a basement or crawl space, or in a valve box underground, and the Extension warns that an underground stop-and-waste may be about 5 feet down, requiring a long key, and that you should not force the valve while opening or closing it. A shutoff that resists is a reason to pause and get help, not to add leverage; breaking the one valve that isolates your irrigation from the house supply turns a maintenance afternoon into a plumbing emergency.

If your irrigation shutoff is indoors, drain the section between the shutoff and the outside line as well, and leave a bucket beneath an indoor drain if your setup has one that drips as it empties. While you are working on water inside the house, the same freeze logic applies to the rest of your plumbing: the room-by-room audit in our guide to keeping pipes from freezing in winter covers the indoor runs, cabinets, and crawl spaces that share a wall with your irrigation supply line.

Do not set the controller yet if you plan to blow out the system. Rain Bird’s blowout procedure uses the controller to activate zones one at a time, and instructs you not to turn the controller off at any point during the process until the compressor is shut off. The controller gets its winter setting at the end, not the beginning. If you are draining by gravity only, with no blowout, you can move to the controller sooner, but leaving it able to run one zone is still useful in the next step, because opening a zone valve is how you relieve mainline pressure.

Step 2, by valve type A: manual drain valves

Use this procedure if your system has manual drain valves or drain caps, and follow Rain Bird’s sequence exactly, because the order is a safety sequence, not a preference. Rain Bird also reminds you to wear eye protection for this task, since the drain valve is pressurised until you relieve it.

  • 1. Turn off the mainline shutoff valve for the sprinkler system, as completed in Step 1.
  • 2. Open one control valve, either manually or electronically from the timer, to relieve pressure on the sprinkler system mainline. Do not skip this step and go straight to the drain; relieving pressure first is what makes opening the drain safe.
  • 3. Slowly open the manual drain valve. Rain Bird capitalises the slowly, and for good reason: a drain cracked open gently lets water and remaining pressure escape in a controlled stream, while a drain thrown open can spray and surge.
  • 4. Repeat for every manual drain valve on the mainline. Missing one low point leaves one trapped section full, and that section is the one that freezes.

Give gravity time to work. Water leaving a long mainline through a small drain does not finish in seconds, and a drain that has slowed to a drip may still be emptying a low section. While drains are open, walk the line if you can and pull up sprinkler heads on systems fitted with check valves, or lift fittings where your installer designed them to be raised for draining; HGTV notes that fittings can crack if water is still sitting in the tubing, and that elevating fittings slightly helps ensure they are fully drained. When every drain has stopped, you face the honest limit of this method: you cannot see inside buried pipe. On a system laid perfectly to grade, draining may be sufficient. On an older system, or one with electric valves, treat this as the first stage and continue to the blowout in Step 4.

What about the water between the shutoff and the backflow preventer? That short section does not drain through the mainline drains. It is handled with the backflow procedure below, by opening the drain cap on the stop-and-waste valve where one is fitted and opening the test cocks on the device. Do not declare the system drained until that section has been dealt with too, because it is above ground or near the foundation in many homes and freezes earlier than anything buried.

Step 2, by valve type B: automatic drain valves

Rain Bird describes the automatic drain valve as a spring-loaded device installed on the sprinkler heads or pipes, which removes water from the system every time it is shut off. Because of that, Rain Bird says you should not need to manually intervene for the lateral lines: shutting off the water supply and relieving pressure is the trigger, and the drains open on their own as pressure falls. Your procedure is therefore shorter, but it is a verification procedure, not a day off.

  • Shut off the water supply as in Step 1, then run or open one zone briefly so pressure drops and the automatic drains trigger.
  • Walk every zone and look for the drains doing their job. Water should weep from the low heads or drain points after shutdown. A zone that stays silent and a low head that stays full are both worth investigating.
  • Check for excessive puddling around heads or along lines. Rain Bird lists surface puddling as the sign that a drain has become stuck open; a stuck-open drain wastes water all season, and its presence tells you the drains on this system are ageing and may also stick closed.
  • Still drain the mainline and backflow by hand. Automatic drains belong on lateral lines, not as your only protection for the mainline and the above-ground assembly; use the manual steps for those parts.

Then apply the cold-climate caveat without softening it: Colorado State University Extension says not to trust automatic drain valves as the sole method, because they depend on pipe that was laid to an even grade and has not shifted, and because electric valves trap water above the valve diaphragm that gravity cannot remove. If your winters bring prolonged freezing and your system has electric valves, the automatic drains are a helpful first stage and the blowout is still the finishing step. If your system was professionally designed for automatic drainage, has no electric-valve trap, and your installer directs you to rely on it, follow that installer’s directions for your system; the point of this section is that the decision should be deliberate, not assumed.

Step 2, by valve type C: systems with no drains you can find

Some systems have no accessible manual drains, no automatic drains you can verify, and no drawing showing where anything is. That is common in homes where the system was installed by a previous owner. In that case, do not invent a drain procedure and do not open fittings at random hoping one of them is a drain; opening the wrong fitting on a pressurised line is exactly the injury Rain Bird’s eye-protection warning is about. Your options are the blowout method below, which does not depend on drain valves at all because it pushes water out through the heads themselves, or a professional winterization visit, during which you should ask the technician to map and label every valve for future years. Either way, Step 1 still applies first, and the backflow procedure still applies at the end.

Step 3: set the compressor by pipe type, not by feel

Before the blowout sequence, settle the two numbers that decide whether it helps or harms: pressure and volume. They are not interchangeable. Pressure is the force; volume, measured in cubic feet per minute (CFM), is how much air you can keep delivering. Colorado State University Extension warns that if insufficient volume is used, the air rides over the top of the water after forcing some of it out, and the remaining water drains back into low spots and stays subject to freeze damage. That is the failure mode of a small shop compressor that proudly reaches a high pressure on its gauge: it can hit the number, briefly, and still leave every low section full.

Pipe or situation Pressure limit from the source Source
Flexible black polyethylene pipe Maximum 50 psi Colorado State University Extension; HGTV gives the same cap
Rigid white PVC pipe Maximum 80 psi Colorado State University Extension; HGTV gives the same cap
General ideal range for the compressor 40 to 80 psi, set on the regulator Colorado State University Extension
Rain Bird’s step-by-step blowout procedure Set the pressure regulating valve to 50 psi; air pressure should not exceed 50 psi Rain Bird homeowner guidance
Any zone, regardless of pipe Stay below the rating of the lowest-rated component on that zone, including the nozzles; excess pressure can blow nozzles off Colorado State University Extension

The practical reading of that table is conservative and simple: if you do not know your pipe type for certain, or your zones mix pipe and components, set the regulator to 50 psi as Rain Bird’s procedure directs and work with volume and repeat cycles instead of force. Treat 80 psi as a ceiling that applies only to rigid PVC systems whose weakest component is rated for it, never as a target to aim at. When Rain Bird’s own page also mentions higher regulated ranges for large systems in a general discussion, its actual step-by-step procedure is the part to follow as a homeowner: 50 psi, gradually increased airflow, short cycles.

For volume, use the formula Colorado State University Extension publishes: divide the gallons per minute (GPM) of the zone by 7.5 to get the CFM needed. The Extension works this example: a zone designed for 20 gallons per minute divided by 7.5 gives 2.66, so a compressor capable of providing 2.66 CFM at that pressure is required. If you do not have the irrigation plan with zone GPM marked, the Extension says a quick estimate can be made by adding up the GPM rating for each sprinkler head nozzle on the zone, using the manufacturer’s published nozzle data. The Extension’s rule of thumb for checking your setup in action is equally useful: if the sprinkler heads stay up after the water is blown out and compressed air continues to flow, you are using the right size compressor. Heads that pop up, spit, and fall back while air is still connected are telling you the volume is not there.

One prohibition follows from the volume problem. Never charge a small tank fully and dump that stored burst into the mainline to compensate for low CFM. You would be trading the thing you lack, sustained volume, for the thing you must limit, a pressure spike, and the spike arrives with every valve and fitting closed in front of it unless a zone is open. Rent or borrow a compressor sized by the formula, or hire the blowout out. The same seasonal logic applies to your other outdoor water equipment: a pressure washer holds water in its pump the same way, which is why owners comparing medium-duty pressure washers for home use should plan to drain and store those machines for winter too, following their own manuals.

AI-generated illustration of a How to Winterize Your Sprinkler System by Valve Type

Step 4: blow out the lines, zone by zone

Connect the compressor correctly before any zone work begins. Colorado State University Extension directs you to connect the compressor to the downstream blowout fitting, with the isolation ball valve on the downstream side of the backflow device closed, and adds that if the backflow device does not have a blowout fitting on its downstream side, one will need to be added before the system can be blown out. HGTV gives the homeowner version of the same rule: close the valves on the backflow preventer so compressed air cannot reach it, because the air can damage it. Air goes into the zones, never through the backflow device. That single connection rule protects the most expensive component on the system.

Blowout sequence when you activate zones from the controller

  • 1. Close the mainline sprinkler shutoff valve if it is not already closed from Step 1.
  • 2. Relieve mainline pressure by activating a zone from the controller. Rain Bird specifies activating the circuit that is furthest from the air connection before blowing air into the piping.
  • 3. Attach the air compressor hose to the blowout adapter, downstream of the backflow preventer.
  • 4. Set the pressure regulating valve to 50 psi, per Rain Bird’s procedure, subject to the pipe limits in the table above.
  • 5. Turn the compressor on and gradually increase the airflow until the sprinkler heads pop up. Gradual is the operative word; Rain Bird does not describe opening the air all at once.
  • 6. Run that zone for no more than 2 minutes at a time. Rain Bird warns that heat from the compressed air can damage pipes and other components, and specifically cautions against running air too long with gear-drive rotors, because it can heat the rotor wiper seal and melt the rotor head together.
  • 7. Advance the timer to the next zone. Do not turn the controller off at any time during this process until the compressor is shut off, per Rain Bird.
  • 8. Repeat the cycle two or more times per zone, until nothing more than a fine mist appears from the heads. That mist, not silence and not a dry rattle, is Rain Bird’s finishing signal.
  • 9. Leave one zone on while you shut off the compressor, then unhook the compressor from the adapter.
  • 10. Only now turn the timer to OFF.

Blowout sequence when you activate valves manually

If your system has no electric valves connected to a controller, Rain Bird publishes a parallel manual sequence. Close the main shutoff valve, then slowly open the manual handle on one zone control valve to relieve water pressure on the mainline. Attach the compressor hose to the blowout adapter and set the regulating valve to 50 psi. Turn on the zone you want to blow out, turn the compressor on, and gradually increase airflow until the heads pop up. After no more than 2 minutes, turn the compressor off and allow all air to purge completely from the tank and the system. Then open the next control valve, close the previous one, and repeat until you have completed two or more cycles per zone and only a fine mist comes from each head. Finally, turn the compressor off and let any remaining air disperse before touching the hose or valves, then unhook it.

Colorado State University Extension adds three refinements that apply to both sequences. Each zone should be blown out twice, and it is better to use two short cycles per zone than one long cycle. Once a zone is blown out, avoid blowing it again beyond those planned cycles, because compressed air moving through dry pipes causes friction and heat that can cause damage. And if you normally run one zone at a time when irrigating, blow the system out the same way; trying to push air through several zones at once raises velocity and friction heat in the pipe and fittings. The goal was never to remove literally every molecule of water. Rain Bird says plainly that you do not need to blow every single drop out. A fine mist at the heads and no standing water in low sections is the standard; chasing absolute dryness with endless air time is how seals melt.

Step 5: drain and protect the backflow preventer, by type

Colorado State University Extension notes that if your irrigation system is attached to domestic water, it is required to have a backflow prevention device, the assembly that stops irrigation water from flowing back into drinking water. How you winterize it depends entirely on which type you identified in Step zero, and getting the type wrong in one direction is destructive: the Extension states that Pressure Vacuum Breaker (PVB) and Reduced Pressure (RP) devices must never be blown out with compressed air, because the rubber seals inside can easily melt from the heat of the air.

Atmospheric Vacuum Breaker (AVB)

The Extension says AVB devices are installed downstream of each valve and are winterized with compressed air when the zone is blown out, so no separate hand-draining procedure applies. It also cautions that AVBs may not be legal in your area, and advises checking with your water district, planning or building department, or county health department if you are unsure about yours. That is a code question about an existing installation, not something to change as part of a fall weekend job.

Pressure Vacuum Breaker (PVB)

Drain this one by hand, after the zones are blown out. The Extension explains that a properly designed and installed PVB should drain easily if both the riser before and after the device are empty of water. After the system is blown out, exercise both ball valves and the test cocks, the small valves protruding from the side, back and forth several times. Then leave them in a half-open position for the winter. The reason is precise: ball valves that are either fully closed or fully open tend to trap water, which expands and causes damage. Half open is not indecision; it is the position that leaves no sealed pocket of water inside the valve body. In spring, close the test cocks and ball valves before pressurising, and once the supply is on, open the ball valves slowly to prevent water hammer damage.

Reduced Pressure (RP) device

The RP has two check valves whose zones must be drained separately, and the Extension gives this sequence. Slowly close the main shutoff valve upstream of the device. For the first check zone, closest to the water supply, open test cocks number 2 and number 3 to drain the water between the first and second check valves. Drain all water upstream of the device by opening the stop-and-waste or other drain. For the second check zone, remove the check cap, spring, and disk holder so water downstream of the second check drains through the body, then replace the disk, spring, and check cap. Leave the isolation ball valves at approximately 45 degrees while draining, and leave them in that position for the winter; if the device has optional drain plugs, remove the plugs and test cocks number 2 and number 3. In spring, the ball valves should be fully closed when the system is pressurised, and always opened and closed slowly to prevent water hammer damage.

Whichever type you have, finish the assembly the same way: insulate what sits above ground. Rain Bird’s additional winterizing guidance includes insulating valve boxes and backflow preventers after the system is fully drained, and insulating any above-ground piping and the main shutoff itself so they cannot freeze. Insulation here protects drained but thin-walled parts against the coldest nights and against the small amount of residual moisture no draining method can remove. It is the same principle, applied at house scale, as the whole-house sequence in our guide to winterizing your home before the first freeze: drain what holds water, insulate what stays exposed, and do both before the freeze rather than after it is forecast.

Step 6: the pump, the controller, and the loose ends

The pump. If your system has a pump, Colorado State University Extension directs that it should be drained, removed from the system, and stored inside. If removal is not possible, drain the pump and wrap it to insulate it from the weather. A pump case full of water is one of the parts the Extension lists as splitting open when water freezes, so draining it is not optional in either branch of that instruction. Indoor storage space matters here; a drained pump, your removed faucet timers, and your hoses all need a non-freezing home for the season, which is worth arranging before the day itself rather than improvising a corner of the garage that night.

The controller. Set it so it will not run zones with the water off, but do not unplug it. Colorado State University Extension says the irrigation controller should remain powered during the winter, because heat from the transformer can help reduce moisture and protect components from corrosion. The Extension also recommends programming the controller to run through a minimum cycle once a week to help keep solenoid plungers from sticking. HGTV offers the complementary homeowner tip: if your timer has a rain mode or standby setting, choose it instead of switching fully off, so you do not have to reprogram your watering schedule in spring. Rain Bird’s own sequence ends with the timer turned to OFF after the blowout; follow your controller maker’s winter setting where it differs, but keep the unit powered either way.

Hoses, faucets, and faucet-side equipment. HGTV directs that after draining, you should remove any faucet assembly, including the timer, filter, and pressure regulator, and store those items indoors protected from freezing temperatures, sealing the open faucet end with a female hose fitting or a secure cover so dirt and animals cannot enter over winter. For garden hoses, HGTV advises removing watering wands, draining the hose by unwinding it with the end down-slope so it empties as you wind it, and storing it in a shed or garage. Shut off water to exterior faucets at the interior valve, open the outside faucet until the line drains, and cover it with an insulated faucet cover. Working through this list in cold wind is miserable with bare hands, so it is a reasonable moment to use the insulated work gloves made for outdoor winter jobs rather than thin garden gloves that soak through at the first drain valve.

Final walk-around checklist. Before you call the job done, confirm each line against your own system rather than against this list in the abstract.

  • Main irrigation shutoff closed, and the indoor section drained where a drain is fitted.
  • Mainline drains opened in sequence, or automatic drains verified working, zone by zone.
  • Every zone blown out in two or more short cycles, no zone run longer than 2 minutes at a time, ending at a fine mist.
  • Compressor disconnected, remaining air purged, and no valve left pressurised.
  • Backflow preventer drained by hand for PVB or RP types, ball valves and test cocks left half open, assembly insulated.
  • Pump drained and stored inside, or drained and wrapped in place.
  • Controller set to OFF or rain mode, still plugged in and powered.
  • Faucet timers, filters, and regulators removed and stored indoors; hoses drained; exterior faucets shut off inside, drained, and covered.
  • Valve positions photographed or noted for spring startup, when ball valves must be opened slowly.

That checklist is also your spring document. Several winter positions are deliberately wrong for operation, including half-open ball valves and open test cocks, and Colorado State University Extension’s spring instructions depend on reversing them in order and pressurising slowly. File the photo and the checklist together, ideally with a note of which compressor size and pressure you used, because that record turns next fall’s job from an investigation into a repeat performance. The same record-keeping habit helps with the rest of the yard’s winter fleet; owners putting away mowing and snow equipment together often store it all in one place, as in the sheds covered by our guide to storage sheds sized for riding lawn mowers, and drained, labelled equipment survives that shared storage far better than equipment put away wet.

Mistakes to avoid, and the safety warnings that matter

Blowing air through the backflow preventer. This is the most expensive single error. PVB and RP seals can melt from the heat of compressed air, per Colorado State University Extension, and HGTV likewise warns to close the backflow valves so air cannot reach the device. Connect downstream of it, always.

Using pressure your pipe cannot take. Exceeding 50 psi on polyethylene or 80 psi on PVC, or exceeding the rating of the lowest-rated nozzle or component on a zone, risks blowing nozzles off and cracking fittings, per the Extension. If you remember only one number, remember Rain Bird’s procedural setting of 50 psi.

Trusting a small compressor because its gauge reads high. Pressure without volume lets air ride over the water and leaves the low spots full, per the Extension. Size by the GPM divided by 7.5 formula, and check that heads stay up while air flows.

Running one long cycle instead of short ones. Heat is the hidden cost of air time. Rain Bird caps each circuit at 2 minutes, warns that heat can warp pipes and fittings and melt gear-drive rotor seals, and the Extension advises two short cycles per zone rather than one long one, and no re-blowing of dry pipe.

Opening a manual drain before relieving pressure. Rain Bird’s sequence exists because a pressurised drain can injure you. Zone valve first, drain second, slowly.

Leaving backflow ball valves fully open or fully closed. Both positions trap water in the valve body, per the Extension. Half open, about 45 degrees on an RP, is the winter position.

Unplugging the controller. You lose the transformer heat that keeps moisture and corrosion down, per the Extension, and on some timers you lose or scramble the program you will want in spring.

Forcing a stuck shutoff. The Extension says not to force a stop-and-waste valve. A broken shutoff converts a controlled job into an emergency shutoff of the whole house supply.

Starting after the freeze. Winterizing removes water so it cannot freeze; it does not repair a pipe that already has. If you suspect a line froze before you drained it, shut the water off and inspect in spring before pressurising, opening valves slowly as the Extension directs, and watch for the leaks that reveal freeze damage. And if any part of the pressurised-air work is beyond your equipment or confidence, Rain Bird’s advice stands: contact a professional. A service visit is a known, bounded cost; a burst mainline discovered in spring is not. The rest of the winter yard, from the irrigation manifold to the battery snow blowers used on gravel driveways, rewards the same approach: prepare it before the weather forces the issue, not during it.

Frequently asked questions

Can I winterize with drain valves alone, without a blowout?

Sometimes, on a system designed and still graded for gravity drainage, but you cannot verify it from the surface. Colorado State University Extension says not to trust manual or automatic drain valves alone, because buried pipe shifts and trapped low spots cannot be inspected, and states that systems with electric valves must be blown out because only air clears water from the top of the valve diaphragm. In a cold climate, draining plus a blowout is the defensible combination.

What pressure should I set on the compressor?

Follow Rain Bird’s step-by-step setting of 50 psi unless you know your system well enough to use the pipe-specific ceilings: Colorado State University Extension lists a maximum of 50 psi for flexible polyethylene pipe and 80 psi for rigid PVC, within a general range of 40 to 80 psi, and always below the rating of the lowest-rated component on the zone. Never treat 80 psi as a default.

How long should I blow out each zone?

Rain Bird says no more than 2 minutes at a time per circuit, repeated for two or more cycles per zone until only a fine mist appears from the heads. Colorado State University Extension likewise advises two short cycles per zone rather than one long cycle, and warns against continuing to blow a zone that is already dry, because air moving through dry pipe creates friction and heat.

Why must the backflow preventer be drained by hand?

Because compressed air can destroy it. Colorado State University Extension states that PVB and RP devices must never be blown out with compressed air, since the rubber seals inside can melt from the heat of the air. Drain a PVB by exercising its ball valves and test cocks and leaving them half open; drain an RP by its test-cock and check-valve sequence, leaving its ball valves at about 45 degrees.

Should I unplug the controller for winter?

No. Colorado State University Extension says the controller should remain powered, because heat from its transformer helps reduce moisture and protect components from corrosion, and recommends a minimum weekly cycle to keep solenoid plungers from sticking. Turn the timer to OFF at the end of the blowout, as Rain Bird directs, or use rain mode if your timer offers it, per HGTV, but leave it plugged in.

What if I cannot find any drain valves or a blowout fitting?

Do not improvise openings on a pressurised system. Colorado State University Extension notes that if a backflow device has no downstream blowout fitting, one must be added before the system can be blown out. That, and a system you cannot identify at all, are the clear cases for hiring an irrigation professional for this year’s winterization and having every valve mapped and labelled during the visit.

Conclusion

Winterizing a sprinkler system is a sequence, and the sequence is set by your valves. Identify the drain type, zone valves, shutoff, and backflow device first. Shut the water off without forcing anything. Drain by the procedure that matches your valves, relieving pressure before opening any manual drain and verifying automatic drains instead of assuming them. Blow out electric-valve and check-valve systems zone by zone at a regulated 50 psi in Rain Bird’s procedure, in cycles of no more than 2 minutes, until only a fine mist remains. Drain PVB and RP backflow preventers by hand, leave their valves half open, and insulate everything above ground. Finish with the pump drained, the controller powered but off, and a written record for spring. Do those steps in that order, before the first hard freeze, and the system that greets you in spring is the same one you put to bed in fall, with no cracked fittings hiding underground waiting for the first pressurised morning to announce themselves.