Key takeaways

  • Seven laboratory freezers for science compared, from 3.5 to 25 cubic feet, with ultra-low ranges to minus 86 degrees C and alarm details for each model.

A laboratory freezer has to hold a steady temperature for years, and the keyword best laboratory freezers for science points at lab freezers built for samples, reagents, and vaccines. We compared seven models from 3.5 to 25 cubic feet, from ultra-low units at minus 86 degrees C to a minus 30 degrees C lab freezer, and listed what each page states.

Quick verdict

The Haier DW-86L578J is the largest ultra-low freezer in this guide, with 578 litres and a range down to minus 86 degrees C. The Eppendorf CryoCube F570 is the best large pick, with 570 litres, five compartments, and room for 400 boxes. The Summit VT65 is the best small pick, with 3.5 cubic feet and a range down to minus 30 degrees C.

Model Capacity Temp range Defrost Energy Box capacity
Helmer HLF125-GX 25.2 cu ft -15 to -30 degrees C Automatic 8.77 kWh/day 4 shelves
So-Low U85-22 22 cu ft / 626 L -40 to -85 degrees C Manual Not stated 25 racks
Haier DW-86L578J 578 L / 20.4 cu ft -40 to -86 degrees C Manual 700-1000 W Not stated
Eppendorf CryoCube F570 570 L / 20.1 cu ft -50 to -86 degrees C Not stated Not stated 400 x 2-in boxes
Thermo Scientific TSX 400 549 L / 19.4 cu ft -40 to -86 degrees C Manual 8.21 kWh/day 400 x 2-in boxes
PHCbi MDF-DU503VHA-PA 528 L / 18.6 cu ft -40 to -86 degrees C Not stated 4.99 kWh/day 384 x 2-in boxes
Summit Accucold VT65 99 L / 3.5 cu ft -20 to -30 degrees C Manual Not stated 3 drawers

How we selected

Every freezer in this guide is a laboratory freezer the maker or listing page describes for science, research, or vaccine storage, with a stated capacity and a stated temperature range. We opened the maker or listing page for each model and read the capacity, the temperature range, the box count, and the energy use straight from the page.

Where a page did not state a figure, the article says so. Seven models met the bar, and each section below lists what its own page states and what it leaves out.

Seven laboratory freezers for science

Seven laboratory freezers for science are below, ordered from largest to smallest by capacity. Every model here is built for a lab, and every figure comes from the maker or listing page we opened for that model. The two minus 30 degrees C models sit at the end of the list.

Helmer HLF125-GX 25.2 cubic feet

The Helmer HLF125-GX is the largest laboratory freezer in this guide, with 25.2 cubic feet, a temperature range of minus 15 to minus 30 degrees C, and a set point of minus 30 degrees C. It has four ventilated shelves, automatic defrost, and a digital microprocessor controller. It weighs 441 pounds and uses 8.77 kilowatt-hours per day.

The listing page calls this model a Horizon Series minus 30 degrees C laboratory freezer, and the specifications list an interior volume of 25.2 cubic feet and a temperature range of minus 15 to minus 30 degrees C. The set point is minus 30 degrees C, the uniformity is plus or minus 2.0 degrees C, and the stability is 0.1 degrees C. The pull-down time to minus 30 degrees C is 65 minutes, and the recovery to minus 29.5 degrees C after a 1-minute door opening is 21 minutes. The page lists the model as not discontinued, and the listing page shows conflicting availability, so confirm availability before you buy.

  • Temperature range: minus 15 to minus 30 degrees C, set point minus 30 degrees C
  • Capacity: 25.2 cubic feet, 4 ventilated shelves
  • Defrost: automatic, programmable up to 4 daily defrost events
  • Energy: 8.77 kilowatt-hours per day, 52 decibels
  • Alarms: power failure, high and low, door ajar, remote alarm contacts, 9-volt battery backup
  • Size and weight: 30.2 by 38.6 by 80.3 inches, 441 pounds

So-Low U85-22 22 cubic feet

The So-Low U85-22 is a 22-cubic-foot ultra-low laboratory freezer, with a temperature range of minus 40 to minus 85 degrees C and a digital dual display. It has five stainless steel inner doors, four adjustable shelves plus a base shelf, and room for 25 inventory racks. It runs on 115, 208, or 230 volts and has four lockable casters.

The listing page calls this model a 22-cubic-foot minus 85 degrees C ultra-low temperature laboratory freezer, and the capacity is 626 litres. The temperature range runs from minus 40 to minus 85 degrees C, and the digital dual display shows the temperature. The audible high and low alarm covers temperature, and the page lists power failure and low battery alarms with a backup battery that powers the alarm only. The listing page shows availability as in stock.

  • Temperature range: minus 40 to minus 85 degrees C
  • Capacity: 22 cubic feet, 626 litres, 25 inventory racks
  • Defrost: manual, gravity flow air circulation
  • Doors and shelves: 5 stainless steel inner doors, 4 adjustable shelves plus a base shelf
  • Alarms: audible high and low, power failure, low battery, dry contacts
  • Size: 41.25 by 37 by 79.5 inches, 4 lockable casters

Haier DW-86L578J 578 litres

The Haier DW-86L578J is a 578-litre ultra-low laboratory freezer, with a temperature range of minus 40 to minus 86 degrees C and manual defrost. It has three shelves, four inner doors, a USB interface, and a noise level of 50 decibels. It weighs 300 kilograms and draws 700 to 1000 watts.

The listing page calls this model a 578-litre ultralow minus 86 degrees C freezer, and the temperature range runs from minus 40 to minus 86 degrees C. The cooling type is direct cooling, the defrost mode is manual, and the refrigerant is a natural hydrocarbon. The vacuum insulation panels and the five-layer door seal gasket reduce heat gain, and the pressure equalization port allows immediate door reopening after closing. The listing page shows availability as in stock.

  • Temperature range: minus 40 to minus 86 degrees C
  • Capacity: 578 litres, 20.4 cubic feet, 3 shelves, 4 inner doors
  • Power: 115 or 208 to 230 volts, 700 to 1000 watts, 12 or 7.5 amps
  • Noise: 50 decibels
  • Alarms: high and low temperature, door ajar, power failure, hot condenser, high ambient temperature, sensor error, low battery
  • Size and weight: 35.6 by 38.6 by 77.2 inches, 300 kilograms

Eppendorf CryoCube F570 570 litres

The Eppendorf CryoCube F570 is a 570-litre ultra-low laboratory freezer, with a temperature range of minus 50 to minus 86 degrees C and five compartments. It has five insulated inner doors, walls 130 millimetres thick, and room for 400 freezer boxes.

The maker page calls this series a 570-litre ultra-low freezer, and the temperature range runs from minus 50 to minus 86 degrees C. The five compartments each have an insulated inner door, and the walls are 130 millimetres thick. The two-stage cascade cooling system uses hydrocarbon cooling liquids, and the page states most users put the set point to minus 80 degrees C. The automatic vent port enables fast re-access, and carbon dioxide or liquid nitrogen backup systems are available.

  • Temperature range: minus 50 to minus 86 degrees C
  • Capacity: 570 litres, 20.1 cubic feet, 400 freezer boxes, 25 racks
  • Compartments: 5, each with an insulated inner door
  • Cooling: 2-stage cascade, hydrocarbon liquids R290 and R170
  • Models: F570n air-cooled, F570h with vacuum insulation panels, F570hw water-cooled
  • Monitoring: temperature monitor systems for remote monitoring

Thermo Scientific TSX Universal 400 549 litres

The Thermo Scientific TSX Universal 400 is a 549-litre ultra-low laboratory freezer, with a temperature range of minus 40 to minus 86 degrees C and a set point of minus 80 degrees C. It holds 400 two-inch boxes on 16 racks, has three adjustable shelves, and uses 8.21 kilowatt-hours per day. It has a touch-screen display.

The listing page calls this model an Ultra-Low Freezer 400, and the capacity is 549 litres or 19.4 cubic feet. The temperature range runs from minus 40 to minus 86 degrees C, the set point is minus 80 degrees C, and the temperature stability is 0.2 degrees C. The door opening recovery is 9 minutes at 20 degrees C ambient running at minus 75 degrees C, and the page states the unit reaches minus 80 degrees C in under 5 hours. The energy use is 8.21 kilowatt-hours per day.

  • Temperature range: minus 40 to minus 86 degrees C, set point minus 80 degrees C
  • Capacity: 549 litres, 19.4 cubic feet, 400 two-inch boxes, 16 racks
  • Shelves: 3 adjustable, 1 fixed, 165 pounds per shelf
  • Power: 100 or 230 volts, 50 or 60 hertz, 8.9 to 4.9 amps, 938-watt compressor
  • Alarms and backup: audible and visual high and low temperature alarms, wireless monitoring, optional carbon dioxide or liquid nitrogen backup
  • Size: 37.6 by 28.3 by 78 inches, 2 rear access ports, 4 locking casters

PHCbi MDF-DU503VHA-PA 18.6 cubic feet

The PHCbi MDF-DU503VHA-PA is an 18.6-cubic-foot ultra-low laboratory freezer, with a temperature range of minus 40 to minus 86 degrees C and a uniformity of plus or minus 3 degrees C at minus 80 degrees C. It holds 384 two-inch boxes on 16 racks, has a touch-screen display, and uses 4.99 kilowatt-hours per day.

The listing page calls this model an 18.6-cubic-foot ultra-low temp freezer, and the temperature control range runs from minus 40 to minus 86 degrees C. The uniformity is plus or minus 3 degrees C at a minus 80 degrees C set point, and the power consumption is 4.99 kilowatt-hours per day at minus 80 degrees C steady state. The dual voltage freezer includes both a 115-volt and a 220-volt power cord, and the maximum amps are 8.5. The listing page shows availability as in stock.

  • Temperature range: minus 40 to minus 86 degrees C, uniformity plus or minus 3 degrees C at minus 80 degrees C
  • Capacity: 18.6 cubic feet, 528 litres, 384 two-inch boxes, 16 racks
  • Energy: 4.99 kilowatt-hours per day at minus 80 degrees C steady state, 52 decibels
  • Power: dual voltage 115 or 220 volts, 8.5 max amps
  • Cooling: cold wall cascade, variable speed compressors, R-290 and R-170
  • Size and weight: 31.1 by 34.7 by 78.5 inches, 531 pounds

Summit Accucold VT65 3.5 cubic feet

The Summit Accucold VT65 is a 3.5-cubic-foot laboratory freezer, with a temperature range of minus 20 to minus 30 degrees C and manual defrost. It has three slide-out drawers, a digital thermostat, and a high and low temperature alarm. It weighs 100 pounds and measures 33.5 by 23.63 by 23.5 inches.

The maker page calls this model a 24-inch wide all-freezer, and the capacity is 3.5 cubic feet or 99 litres. The temperature range runs from minus 20 to minus 30 degrees C, and the digital thermostat sits in the kickplate so the temperature can be managed without opening the door. The three slide-out basket drawers offer storage while keeping the temperature stable when the door is open. The page states an estimated time to ship of 5 to 7 days.

  • Temperature range: minus 20 to minus 30 degrees C
  • Capacity: 3.5 cubic feet, 99 litres, 3 slide-out drawers
  • Defrost: manual, static operation
  • Power: 115 volts AC, 60 hertz, 1.3 amps
  • Alarms: high and low temperature alarm with external temperature readout
  • Size and weight: 33.5 by 23.63 by 23.5 inches, 100 pounds

Buying guide

Pick a lab freezer by temperature first, then by capacity, then by the monitoring and backup features that matter to you. The guide below walks through temperature range, capacity and boxes, energy use, alarms and monitoring, and defrost, using the figures from the pages we opened.

Laboratory freezers for science: ultra-low or minus 30

Five models reach minus 85 or minus 86 degrees C, and two reach minus 30 degrees C. The ultra-low models hold from minus 40 to minus 86 degrees C, except the Eppendorf, which starts at minus 50 degrees C, and the So-Low, which stops at minus 85 degrees C. The Helmer and the Summit hold from minus 15 and minus 20 degrees C to minus 30 degrees C.

Ultra-low freezers suit samples that need minus 80 degrees C, and minus 30 degrees C freezers suit vaccines, reagents, and controls. The TSX, Eppendorf, PHCbi, and Haier reach minus 86 degrees C, the So-Low reaches minus 85, and the Helmer and Summit reach minus 30. The TSX and PHCbi set point is minus 80 degrees C, and the Helmer set point is minus 30 degrees C.

Capacity and box storage compared

Capacity runs from 3.5 cubic feet to 25.2 cubic feet in this guide. The Summit holds 3.5 cubic feet, the PHCbi holds 18.6, the TSX holds 19.4, the Eppendorf holds 20.1, the Haier holds 20.4, the So-Low holds 22, and the Helmer holds 25.2. Box counts run from 384 to 400 two-inch boxes on the ultra-low models that state a count.

Box counts matter more than litres for a busy lab. The Eppendorf and the TSX each hold 400 two-inch boxes, the PHCbi holds 384, and the So-Low holds 25 inventory racks. The Helmer has four ventilated shelves, the Haier has three shelves and four inner doors, and the Summit has three slide-out drawers. Measure the rack size before you buy.

Energy use and noise

Three models state a daily energy figure, and four do not state one. The PHCbi uses 4.99 kilowatt-hours per day at minus 80 degrees C, the Helmer uses 8.77 kilowatt-hours per day, and the TSX uses 8.21 kilowatt-hours per day. The Eppendorf, Haier, So-Low, and Summit pages do not state a daily energy figure.

Daily energy runs from 4.99 to 8.77 kilowatt-hours per day on the three models that state a figure. The PHCbi uses 4.99 at minus 80 degrees C, the TSX uses 8.21, and the Helmer uses 8.77. The Haier draws 700 to 1000 watts, the Summit draws 1.3 amps, and the Eppendorf and So-Low pages do not state a power figure. Noise figures are 50 decibels for the Haier and 52 for the PHCbi and the Helmer.

Alarms, monitoring, and backup systems

Every model here has an alarm. The Summit and the TSX have audible and visual high and low temperature alarms, the So-Low adds power failure and low battery alarms, and the Haier adds door ajar, hot condenser, and sensor error alarms. The Helmer adds a door ajar alarm, a power failure alarm, and remote alarm contacts.

Alarms warn you before samples are lost. The Summit and the TSX have audible and visual high and low temperature alarms, the So-Low adds power failure and low battery alarms, and the Haier adds door ajar, hot condenser, and sensor error alarms. The Helmer adds remote alarm contacts and a 9-volt battery backup, and the PHCbi has a touch-screen display with a USB port for logged data.

Defrost and door access

Four models state manual defrost, one states automatic defrost, and two do not state a defrost type. The TSX, Haier, So-Low, and Summit state manual defrost, and the Helmer states automatic defrost with up to four daily defrost events. The Eppendorf and PHCbi pages do not state a defrost type.

Manual defrost means you melt the frost yourself, and automatic defrost runs on a schedule. The TSX, Haier, So-Low, and Summit state manual defrost, and the Helmer states automatic defrost with up to four daily defrost events. The Eppendorf page states quick pull-down times enable fast re-use after cleaning or defrosting, and the PHCbi page does not state a defrost type.

FAQ

Buyers ask the same questions about laboratory freezers for science again and again, mostly about temperature, box storage, and power. The answers below use the figures from the pages we opened, not general claims about lab freezers everywhere. Read the model sections first if you want the full figures behind an answer.

Which laboratory freezer for science holds the most boxes

The Eppendorf CryoCube F570 and the Thermo Scientific TSX Universal 400 tie at 400 two-inch boxes, the most in this guide. The PHCbi MDF-DU503VHA-PA holds 384 two-inch boxes, and the So-Low U85-22 holds 25 inventory racks. The Haier, Helmer, and Summit pages do not state a box count.

The Eppendorf CryoCube F570 and the Thermo Scientific TSX Universal 400 each hold 400 two-inch boxes, the most in this guide. The PHCbi holds 384 two-inch boxes, and the So-Low holds 25 inventory racks. The Haier, Helmer, and Summit pages do not state a box count, so check the rack size for those models.

What temperature do lab freezers reach

Ultra-low lab freezers reach minus 85 or minus 86 degrees C, and minus 30 degrees C freezers suit vaccines and reagents. Five models in this guide reach minus 85 or minus 86 degrees C, and two reach minus 30 degrees C. The set point on the TSX and the PHCbi is minus 80 degrees C, and the Helmer set point is minus 30 degrees C.

Ultra-low lab freezers reach minus 85 or minus 86 degrees C, and minus 30 degrees C freezers suit vaccines and reagents. Five models in this guide reach minus 85 or minus 86 degrees C, and two reach minus 30 degrees C. The set point on the TSX and the PHCbi is minus 80 degrees C, and the Helmer set point is minus 30 degrees C.

Do lab freezers need a backup system

A backup system is optional on most ultra-low freezers in this guide, not standard. The TSX, Eppendorf, and Haier pages list optional carbon dioxide or liquid nitrogen backup systems. The PHCbi page lists three access ports, including one for a backup system, and the So-Low page does not state a backup option.

A backup system is optional on most ultra-low freezers in this guide, not standard. The TSX, Eppendorf, and Haier pages list optional carbon dioxide or liquid nitrogen backup systems. The PHCbi page lists three access ports, including one for a backup system, and the So-Low page does not state a backup option. Plan the gas supply line before installation if you add a backup.

How much power does an ultra-low freezer use

Daily energy runs from 4.99 to 8.77 kilowatt-hours per day on the three models that state a figure. The PHCbi uses 4.99 kilowatt-hours per day at minus 80 degrees C, the TSX uses 8.21, and the Helmer uses 8.77. The Haier draws 700 to 1000 watts, the Summit draws 1.3 amps, and the Eppendorf and So-Low pages do not state a power figure.

Daily energy runs from 4.99 to 8.77 kilowatt-hours per day on the three models that state a figure. The PHCbi uses 4.99 kilowatt-hours per day at minus 80 degrees C, the TSX uses 8.21, and the Helmer uses 8.77. The Haier draws 700 to 1000 watts, the Summit draws 1.3 amps, and the Eppendorf and So-Low pages do not state a power figure.

Can a lab freezer run on standard voltage

Most models in this guide run on standard 115-volt power, and some offer a second voltage. The Summit runs on 115 volts, the PHCbi runs on 115 or 220 volts, and the TSX runs on 100 or 230 volts. The Haier runs on 115 or 208 to 230 volts, and the So-Low runs on 115, 208, or 230 volts.

Most models in this guide run on standard 115-volt power, and some offer a second voltage. The Summit runs on 115 volts, the PHCbi runs on 115 or 220 volts, and the TSX runs on 100 or 230 volts. The Haier runs on 115 or 208 to 230 volts, and the So-Low runs on 115, 208, or 230 volts. Check the plug type and the circuit before you buy.

Conclusion

Seven laboratory freezers for science are in this guide, from the 3.5-cubic-foot Summit VT65 to the 25.2-cubic-foot Helmer HLF125-GX. Pick the temperature range your samples need first, then match the capacity and the box count to your inventory. Check the energy use, the alarm set, and the defrost type on the page before you buy.